0
Research Papers

Resistive Spot in a Fuel Cell Stack: Exact Solutions

[+] Author and Article Information
A. A. Kulikovsky

Institute for Energy Research-Fuel Cells (IEF-3), Research Center “Jülich”, D-52425 Jülich, Germany

This is justified provided that the mean current density in a stack is not small, J̃01. From practical point of view, this is the most interesting case.

J. Fuel Cell Sci. Technol 6(1), 011024 (Nov 26, 2008) (6 pages) doi:10.1115/1.2972168 History: Received June 28, 2007; Revised October 24, 2007; Published November 26, 2008

We report the analytical solution to a problem of voltage and current distribution in a two-cell stack with the small amplitude resistive spot in one of the cells. Voltage disturbance in the defective cell increases almost linearly with the characteristic spot radius. The general expression for voltage loss due to a spot in an N-cell stack is obtained; it is stack current density times peak spot resistivity times square of the characteristic spot radius. Based on the solutions derived, a method for spot detection in a stack is discussed.

FIGURES IN THIS ARTICLE
<>
Copyright © 2009 by American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Grahic Jump Location
Figure 1

Sketch of a two-cell stack with the resistive spot in the cell α. The arrows indicate the current lines. Part of the current is transported through the spot and the rest part bypasses the spot moving in plane in the bipolar plate.

Grahic Jump Location
Figure 2

(a) Spot resistivity R̃α1 and (b) dimensionless disturbance of voltage of the cell Ṽα1 due to the spot. Indicated are the characteristic spot radii s̃.

Grahic Jump Location
Figure 3

Voltage disturbance in the spot center Ṽα1(0) as a function of spot radius s̃

Grahic Jump Location
Figure 4

Function F(0)=qexp(q)Ei(1,q)

Grahic Jump Location
Figure 5

Current of the cell α for indicated spot radii s̃.

Grahic Jump Location
Figure 6

(a) Voltage and (b) current of the cells α and β. Spot radius is s̃=0.1; other parameters are listed in Table 1.

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In